Research Article

On the Reliability of Transformerless Photovoltaic DC/AC Converters Based on Mission Profile

Table 13

Percentage of contribution to the failure rate of the photovoltaic system.

Inverter failure rateLCL filter failure rate
TopologySwitchesDiodesCapacitorsInductorsCapacitors
MOSFETParasitic diode

Full bridge97.73%XXX2.21%0.06%
Double buck50.06%X48.77%X1.13%0.04%
H571.00%27.67%XX1.30%0.03%
HERIC74.61%24.23%XX1.13%0.03%
H674.61%X24.22%X1.13%0.04%
NPC66.21%X32.25%X1.51%0.03%
Virtual DC bus98.14%XX0.04%1.78%0.04%

X indicates that it is not applied for the system.