Research Article

Design of Boosted Multilevel DC-DC Converter for Solar Photovoltaic System

Table 5

Harmonic investigation of three-phase BMLDCLC fed RL load (for 120 V).

Order of harmonics
Voltage harmonics (%)Current harmonics (%)Voltage harmonics (%)Current harmonics (%)Voltage harmonics (%)Current harmonics (%)

30.030.050.040.030.020.02
54.873.824.212.715.464.67
74.692.164.062.083.691.81
90.080.040.080.030.070.05
113.631.763.081.452.221.39
133.581.382.671.152.721.17
150.060.030.040.010.090.04
173.320.122.570.891.710.86
193.160.962.460.722.200.65