Comparison of the STC simulation results of the proposed MPPT and INC MPPT schemes.
| | INC MPPT | Proposed MPPT |
| Photovoltaic module output | Power ripple magnitude (W) | 15.9 | Neglected | SSE (W) | 6.55 | 1.6 |
| Boost converter output | Power ripple magnitude (W) | 76 | 10 | Voltage ripple magnitude (V) | 15 | 2.5 | Current ripple magnitude (A) | 0.5 | 0.1 | Time response (s) | 0.028 | 0.011 | Steady-state average efficiency (%) | 94.23 | 99.86 |
|
|