Research Article
An Advanced MPPT Scheme for PV Systems Application with Less Output Ripple Magnitude of the Boost Converter
Table 3
Summary of the simulation results comparison of INC and the proposed MPPT schemes under the Sin scenario.
| Sin test | INC MPPT | Proposed MPPT |
| Average tracking efficiency (%) | 97.87 | 99.62 | Time response (seconds) | 0.028 | 0.012 | Average ripple magnitude of the boost output current (A) | 1.85 | 0.08 | Average ripple magnitude of the boost output voltage (V) | 14.38 | 2 | Average ripple magnitude of the boost output power (W) | 54.52 | 10.62 | Average ripple magnitude of the photovoltaic voltage (V) | 3.5 | Neglected | Average ripple magnitude of the photovoltaic current (A) | 0.35 | Neglected | Average ripple magnitude of the photovoltaic power (A) | 10.8 | Neglected |
|
|