Research Article

An Advanced MPPT Scheme for PV Systems Application with Less Output Ripple Magnitude of the Boost Converter

Table 4

Summary of the performance comparison of the proposed MPPT and INC MPPT schemes during real-time verification using the RT-LAB simulator.

INC MPPTProposed MPPT
Test conditionsSTCSudden insolation change (1➔ 0.5 kW/m2)STCSudden insolation change (1➔ 0.5 kW/m2)

Average tracking efficiency (%)97.8096.599.8097.77
Ripple magnitude of the boost converter output current (A)1.661.66-0.310.630.63-0.31
Ripple of magnitude of the boost converter output voltage (V)17.3317.33-2.36.296.29-2.3
Average ripple of magnitude of the boost converter output power (W)118118-14.956.656.6-14.9
Average ripple magnitude of the photovoltaic voltage (V)2.612.61-neglectedNeglectedNeglected
Average ripple magnitude of the photovoltaic current (A)0.860.86-neglectedNeglectedNeglected
Average ripple magnitude of the photovoltaic power (A)8.88.9-neglectedNeglectedNeglected