Research Article

An Advanced MPPT Scheme for PV Systems Application with Less Output Ripple Magnitude of the Boost Converter

Table 5

Performance comparison of the proposed MPPT scheme with other MPPT schemes.

ScenarioRef [31]Ref [34]Ref [30]INC methodProposed

Steady-state oscillationSmallSmallNeglectedBigNeglected
Static tracking efficiency (%)99.7095.4399.5294.2399.86
Tracking time (s)0.120.080.0160.0280.011
Dynamic tracking efficiency (%)96.6198.9599.6895.2899.60
Tracking velocity under fast change in irradianceMediumMediumFastMediumVery fast