Research Article

Completely Recuperative Supercritical CO2 Recompression Brayton/Absorption Combined Power/Cooling Cycle: Performance Assessment and Optimization

Table 2

Cycle parameter and efficiency value comparison for two absorption systems.

Cycle parametersReference [41]This article
EnergyExergyEnergyExergy

Input heat (kW)373019462719.51185.8
Input heat (kW)667.3204.5338.9118
Turbine generated work (kW)774.7774.7474.8474.8
Refrigeration capacity (kW)298.839.42259.530.5
Pump input work (kW)23.1423.1416.2116.21
Pump input work (kW)9.2759.27500
Pump input work (kW)004.324.32
Overall efficiency (%)24.2437.2824.038.7