Research Article

A Novel Topology to Improve PV Module Efficiency under Partial Shading Conditions

Table 3

Performance factors such as GMP, MPL, FF, and PR of OE [25], LS [26], and KDK arrangement schemes of configuration under different partial shading conditions.

ConfigurationsGMPMPL (%)FF (%)PR (%)Best configuration
Ia (A)Va (V)Pa (W)

DS pattern
OE [25]0.1121.5030.16854.3553.3345.60KDK
LS [26]0.1121.5030.16854.3553.3345.60
KDK0.1331.5030.19946.0063.2054.08
FS pattern
OE [25]0.06252.0040.12566.0339.7033.90KDK
LS [26]0.1122.0040.22439.1371.1060.90
KDK0.1431.8900.27525.387.3074.70
VS pattern
OE [25]0.0892.0040.17851.6056.5048.40OE/LS/KDK
LS [26]0.0892.0040.17851.6056.5048.40
KDK0.0892.0040.17851.6056.5048.40
CS pattern
OE [25]0.1431.8900.27525.3087.3074.70OE/LS/KDK
LS [26]0.1431.8900.27525.3087.3074.70
KDK0.1431.8900.27525.3087.3074.70
CLS pattern
OE [25]0.0670.5010.03391.0310.508.90KDK
LS [26]0.0671.0020.06782.8021.3018.20
KDK0.1121.0020.11269.6035.5035.50
SS pattern A
OE [25]0.1431.5030.21541.6068.2058.40LS/KDK
LS [26]0.1431.8900.27525.3087.3074.70
KDK0.1431.8900.27525.3087.3074.70
SS pattern B
OE [25]0.1341.5030.20145.0063.8054.60KDK
LS [26]0.1381.5030.20744.0065.7056.20
KDK0.1431.8900.27525.3087.3074.7
SS pattern C
OE [25]0.1381.5030.20744.0065.7056.20KDK
LS [26]0.1421.5030.21342.0067.6057.80
KDK0.1431.8900.27525.3087.3074.7
SS pattern D
OE [25]0.1381.5030.20744.0065.7056.20KDK
LS [26]0.1381.5030.20744.0065.7056.20
KDK0.1431.8900.27525.3087.3074.7