Research Article

Design and Implementation of a New Fast and Efficient MPPT Controller under Different Solar Irradiance Conditions

Table 5

Experimental results of PO, PSO, and SMA.

Irradiance conditionMPPT methodVoltage (V)Current (A)Power (W)Power efficiency (%)Tracking time (sec)

UC (1000 W/m2)
PO41.646.31262.7597.01.52
PSO43.906.04265.1897.90.76
SMA45.765.86268.1699.10.53

NUC-1 (300, 400, 200, and 500 W/m2)
PO23.792.5259.9796.41.20
PSO25.292.4160.9798.10.25
SMA25.632.4262.0399.80.24

NUC-2 (500, 800, 700, and 800 W/m2)
PO31.134.67145.4297.01.10
PSO34.884.25148.2698.80.21
SMA35.184.24149.1699.40.21