Research Article

Technical Design and Economic Investigations for Reducing CO2 Emission considering Environmental Protection Agency Standards by Employing an Optimum Grid-Connected PV/Battery System

Table 3

Obtained results for S3.

COE ($/kWh)NPC ($)OC ($/yr.)Initial capital ($)RF (%)PV (kW)Return investment (yr.)Dispatch

S30.1012.06 M9289049445038.528813.13CC
S3T0.1022.03 M9111349570538.523010.96LF