Research Article

Experimental Investigation and Comparison of the Net Energy Yield Using Control-Based Solar Tracking Systems

Table 1

The electrical setup for the experiment.

ComponentModelSpecificationQty

Current sensorASC712Input: 5 V
Frequency: 80 kHz
Sensitivity: 185 mV/A
Error: 1.5%
6
Motor driverL298NInput: 12 V
Operating current: 0-36 mA
Peak current: 2 A
2
Secure digital (SD)SDHCInput: 5 V
Operating current: 0.2-200 mA
2
Real-time clock (RTC)DS3231Input: 5 V
Frequency: 100 kHz
1
Power resistorJIANXIN-09-13-318-02Power rating: 100 W
Resistance value: 8 Ω
Tolerance: 5%
3
On/off switchRating: 3A/6A 250 V
Electrical life: 103 cycles
1
LDRInput: 5 V6
Arduino MegaATmega2560Input: 12 V
Frequency: 16 MHz
1
Linear motorInput: 12 V
Max. speed: 20 mm/s
3
PV module W
 W
 W
 W
3
BatteryCapacity: 100 Ah1