Research Article
Performance Analysis of a Relift Luo Converter-Derived Dual-Output DC to DC Converter for Microgrid Applications
Table 2
Comparison of the time domain observations.
| Load | Peak over shoot (volt) | Steady state error (volt) | Rise time (ms) | Integral square error |
| 96 Watts | 48.2 | 0.45 | 3 | 35.06 | 48 Watts | 48.9 | 0.21 | 5 | 26.51 | 53 Watts | 52 | 1.2 | 4 | 25.99 | 12 V | 50 | 0.8 | 9 | 31.28 | 18 V | 52 | 1.8 | 2.2 | 35.06 | 24 V | 54 | 2.2 | 2 | 31.25 |
|
|