Research Article
Energy Efficiency and Feasibility Analysis of Solar Power Generation Using Hybrid System of an Educational Institution in Malaysia
Table 2
Summary of types of end load, a total of quantity, rating power, and operating hours for routine activity at MED, CED, EED, and CD.
| No | End-load | Department | Quantity | Total power | Average operating hours | (kW) | (h/year) |
| 1 | Laboratory equipment | MED | 1022 | 45.17 | 318 | CED | 100 | 52.335 | 430 | EED | 633 | 14.649 | 436 | CD | 35 | 18.32 | 1124 |
| 2 | Fan | MED | 113 | 0.299 | 708 | CED | 109 | 0.299 | 708 | EED | 102 | 0.299 | 708 | CD | 88 | 0.299 | 788 |
| 3 | Lighting | MED | 2241 | 0.496 | 708 | CED | 1341 | 0.496 | 756 | EED | 2250 | 0.496 | 804 | CD | 1047 | 0.078 | 1432 |
| 4 | Air conditioning (ACSU+WCPU) | MED | 59 | 73.008 | 928 | CED | 14 | 48.656 | 1499 | EED | 89 | 163.653 | 1375 | CD | 18 | 80.113 | 782 |
| 5 | ICT equipment | MED | 186 | 0.378 | 309 | CED | 85 | 0.591 | 495 | EED | 66 | 0.361 | 588 | CD | 32 | 0.346 | 780 |
| Total | MED | 3621 | 119.351 | 2,972 | CED | 1649 | 102.377 | 3,888 | EED | 3140 | 179.458 | 3,911 | CD | 1220 | 99.156 | 4,906 |
|
|