Experimental test results.
|
Group sample |
Number | (%) |
Stirrup | @ Maximum compressive | Avg. ratio | @ Maximum compressive | Strength (kN) | Stress (MPa) | | % of difference | Column axial strain (mm/mm) |
| C-1 SF-sc | 1 2 3 | 1.42 | Spiral (s) | 380 340 390 | 16.9 15.1 17.3 | 1.643 |
0.218 | 0.005 0.004 0.007 | C-2 SN-sc | 1 2 3 | — | Spiral (s) | — 330 310 | — 14.7 13.8 | 1.425 | — 0.005 0.005 |
| C-3 SF-sn | 1 2 3 | 2.05 | Spiral (s) | 360 370 — | 23.0 23.7 — | 2.085 |
0.454 | 0.004 0.004 — | C-4 SN-sn | 1 2 3 | — | Spiral (s) | 240 285 285 | 15.4 18.2 18.2 | 1.631 | 0.005 0.006 0.006 |
| C-5 CF-sc | 1 2 3 | 1.91 | Spiral (s) | 320 — 370 | 18.1 — 21.5 | 1.892 |
0.429 | 0.006 — 0.007 | C-6 CN-sc | 1 2 3 | — | Spiral (s) | 280 270 250 | 15.8 15.3 14.1 | 1.440 | 0.003 0.006 0.007 |
| C-7 CF-sn | 1 2 3 | 2.63 | Spiral (s) | 310 — 320 | 25.3 — 26.1 | 2.427 |
0.463 | 0.004 — 0.004 | C-8 CN-sn | 1 2 3 | — | Spiral (s) | — 250 260 | — 20.4 21.2 | 1.964 | — 0.003 0.005 |
| C-9 SF-tc | 1 2 3 | 1.42 | Tied (t) | 355 375 — | 16.0 16.7 — | 1.635 |
0.228 | 0.003 0.004 — | C-10 SN-tc | 1 2 3 | — | Tied (t) | 320 320 310 | 14.2 14.2 13.8 | 1.407 | 0.006 0.004 0.005 |
| C-11 SF-tn | 1 2 3 | 2.05 | Tied (t) | — 375 360 | — 24.0 23.0 | 2.098 |
0.552 | — 0.007 0.006 | C-12 SN-tn | 1 2 3 | — | Tied (t) | 277 250 270 | 17.7 16.0 17.2 | 1.515 | 0.003 0.006 0.007 |
|
|