Research Article

A Kinetic and Mechanismic Study of Plasma-Induced Degradation of Monochloropropionic Acids in Water by Means of Anodic Contact Glow Discharge Electrolysis

Table 2

Elemental yields of products at 240 min from CGDE of MCPAs.

MCPAConversion (%)ChlorineCarbon
ClMCANDMCACAPDAOxalic acidFormic acidICND

3-MCPA766510181436441
2-MCPA706911023523

: 5.0 mmol/L; inorganic carbon; not determined; the corresponding intermediate products were not detected through the reaction time.