Research Article

Fatigue Fracture Properties and Morphology of Polyoxymethylene (POM) Plates Produced under Moderate Processing Conditions

Table 7

WAXD measurements of the CT specimens analyzed for the contribution of the different diffraction peaks to the total crystallinity.

CT specimensCrystallinity1 (%)(100)2 (%)(105)2 (%)(115)2 (%)(205)2 (%)Amorphous fraction2 (%)

Delrin_CM75.8 ± 0.860.112.22.90.624.2
Delrin_IM_60°C-MT72.6 ± 1.060.410.61.40.127.4
Delrin_IM_90°C-MT_Pos175.1 ± 0.962.011.21.70.224.9
Delrin_IM_90°C-MT_Pos275.9 ± 0.764.110.21.50.224.1
Delrin_IM_110°C-MT74.3 ± 0.361.211.41.60.225.7

Tenac_CM74.8 ± 0.558.612.63.00.725.2
Tenac_IM_60°C-MT70.7 ± 0.757.011.81.70.229.3
Tenac_IM_90°C-MT_Pos170.5 ± 0.856.412.11.70.329.5
Tenac_IM_90°C-MT_Pos271.6 ± 0.658.011.71.70.228.4
Tenac_IM_110°C-MT71.3 ± 0.456.912.31.80.328.7

1Average value ± standard deviation. 2Average value.