Research Article

Numerical Study on Seismic Behavior of Underwater Bridge Columns Strengthened with Prestressed Precast Concrete Panels and Fiber-Reinforced Polymer Reinforcements

Table 4

The characteristic values of calculated L-D hysteresis curves and the error to the test results.

Specimen label
Analysis (kN)Error (%)Analysis (mm)Error (%)Analysis (kN)Error (%)Analysis (mm)Error (%)Analysis (mm)Error (%)

CC47.32.112.910.451.973.027.612.2\\
SCB74.531.0149.1109.80.178.88.80.5411.1
SCC74.22.911.94.0104.13.647.312.10.8411.1

.