Research Article

Function Synergy of Cross-Linked Cationic PVA Polymer to AMPS-Type Fluid Loss Additive Used for Cement-Based Material

Table 4

Fluid loss test 2.

Test no.PVAGB (%BWOC)FLA A (%BWOC)SXY-2 (%BWOC)Fluid loss (mL) (30 minutes)

10.10.50.25122
20.10.750.5046
30.11.00.7535
40.150.50.5058
50.150.750.2565
60.151.00.7533
70.20.50.7537
80.20.750.2533
90.21.00.5034
K167.772.373.3/
K2524846/
K334.73435/
R3338.338.3/

Note: orthogonal test (L9 (33)). Test condition as 30°C, 6.9 MPa, and fluid loss in 30 minutes.