Research Article
Performance Evaluation of Layered Double Hydroxides Containing Benzotriazole and Nitrogen Oxides as Autonomic Protection Particles against Corrosion
Table 6
Values of parameters obtained through attribution of EIS results to equivalent circuits.
| Concentration | System | OCP (V) | (Ω) | (Ω) | (mS) | |
| 0.2% | Control | -0.667 | 1.43 | 105 | 49.3 | 0.804 | BTZ-LDH | -0.660 | 1.50 | 165 | 33.8 | 0.815 | NOx-LDH | -0.507 | 1.50 | 630 | 34.8 | 0.796 | 1.0% | Control | -0.662 | 1.23 | 80 | 15.1 | 0.751 | BTZ-LDH | -0.663 | 1.04 | 310 | 13.8 | 0.709 | NOx-LDH | -0.328 | 1.29 | 1000 | 10.8 | 0.721 | 3.0% | Control | -0.699 | 1.65 | 120 | 46 | 0.81 | BTZ-LDH | -0.692 | 1.25 | 117 | 43.5 | 0.793 | NOx-LDH | -0.122 | 1.65 | 1600 | 12.1 | 0.865 |
|
|