Electrochemical parameters obtained after fitting EIS data of coated samples to equivalent circuit .

Control0.2%1.0%3.0%
Immersion time (h)18181818

OCP (V)-0.447-0.482-0.503-0.484-0.472-0.560-0.515-0.529
(kΩ)60.711.6103013428.14.299.176.16
(μS)23.114001.212564.1843315660
0.5850.4190.6730.5570.5340.1710.5930.278
(kΩ)31.13.3515066.827.51.097.310.697
(μS)2.1422.30.07261.340.86925.716.7199
0.6340.6160.8420.640.6591.020.550.662
(kΩ)2.770.5045016.38.730.8010.6130.124
(μS)0.3665.900.01520.01090.023627.30.2170.091
0.7620.5680.8940.9130.8620.7660.7660.915