Research Article

Thermal and Mechanical Performance of 3-Phase Polymer Composite Panels for Structural Applications

Table 3

Comparison of the structural integrity and insulation of FRP panels and plywood.

Plywood results (literature)Experimental resultsRemarks
ValueRef.PPGPPJ

Thermal conductivity (W/m·K)0.15[33]0.193–0.2140.126–0.14PPJ has lower thermal conductivity and can offer more resistance to heat
Density (kg/m3)325–1050[33]14751095The density of PPJ is comparable to plywood; therefore, weight will be the same
Flexural modulus (GPa)8.2Matweb4.89–5.062.48–2.58The flexural modulus of PPJ is poor and needs improvement, before use for structural application
Drop weight impact (J/g)0.45–0.86[34]0.70–1.22PPG offers more resistance to falling weight and can result in enhanced life
Impact strength (kJ/m2)10.1[35]24.83–43.988.52–10.10PPJ and plywood offer comparable resistance to a low-velocity impact