Research Article

Effects of the Hot Alignment of a Power Unit on Oil-Whip Instability Phenomena

Table 1

Amplitude of the most important harmonic orders of the vibrations measured at the generator bearing no. 1 during an instability onset.

Harmonic Orders
Direction0.26X0.5X1X2X

(4 Right)557.1  m pp13.8  m pp31.8  m pp8.3  m pp
(4 Left)208.6  m pp23.7  m pp26.5  m pp11.8  m pp