Research Article

Numerical Research on Effects of Splitter Blades to the Influence of Pump as Turbine

Table 3

Amplitude of frequency domain and MPF at volute monitoring points (see Figures 7(a) and 7(b)).

ItemsFrequency12345

Without splitter50 Hz2101.526497.022194.449119.441797.85
100 Hz425.34491.59911.751111.941051.60
150 Hz420.67560.64699.092390.07987.26
MPF1.443.731.665.242.03

With splitter50 Hz956.431361.59492.591379.13190.40
100 Hz963.561160.571495.593628.931120.18
150 Hz400.03498.83870.31984.721249.82
MPF1.021.551.253.091.48