Research Article
Flow Modeling in Pelton Turbines by an Accurate Eulerian and a Fast Lagrangian Evaluation Method
Table 1
Comparison of FLS and Fluent computational results.
| Case description | Discharge (% of BEP) | Net head (m) | Runner speed (rpm) | Number of buckets | Eff. VOF (%) | Eff. FLS (%) |
| Reference point | 100 | 100 | 1000 | 22 | 88.3 | 88.5 | Low flow rate | 50 | 100 | 1000 | 22 | 91.2 | 91.3 | High flow rate | 135 | 100 | 1000 | 22 | 86.7 | 86.4 | High hydraulic head | 100 | 156 | 1250 | 22 | 88.2 | 88.5 | Modified runner | 100 | 100 | 1000 | 18 | 85.8 | 85.9 | Different bucket design | 100 | 100 | 1000 | 20 | 94.5 | 95.0 |
|
|