Research Article
A Comparison of Off-Grid-Pumped Hydro Storage and Grid-Tied Options for an IRSOFC-HAWT Power Generator
Table 5
Input parameters for IRSOFC system.
| Component efficiency |
| Combustion chamber | 95 | % | Heat exchanger | 80 | % | Inverter | 96.5 | % |
| Pressure drop |
| Heat exchanger | 1 | % | SOFC | 2 | % | Combustion chamber | 1 | % |
| SOFC input data |
| Area | 0.0834 | m2 | Recirculation ratio | 60 | % | Limiting current density | 9000 | A/m2 | Current density | 2000 | A/m2 | Fuel utilization factor | 85 | % | Air utilization factor | 25 | % |
|
|