Research Article

A Comparison of Off-Grid-Pumped Hydro Storage and Grid-Tied Options for an IRSOFC-HAWT Power Generator

Table 6

Results of IRSOFC modeling.

ā€‰First scenarioSecond scenario

Electrical efficiency%55.355.3
Number of cellsā€‰25542371
SOFC power productionkW272.5253.0