Validation of In-Room UV-C-Based Air Cleaners

Figure 7

(a) Indication of time-course measurements of airborne, infective T1 phage concentration in the IAQ chamber for the air cleaner operated at a nominal air flow rate of 1530 m3/hr (900 cfm) with the filter and the UV lamps both operating. Also included is a fit of the IAQ model to the data. (b) Illustration of the results of least-squares fitting of the model to the data for . The value of CADR for each experiment was identified as the value that provided the “best fit” of the model to the data, based on the minimum value of the residual sum of squared errors (RSS). The value of F for each experiment was then defined by application of a rearranged form of equation (15).
(a)
(b)