Research Article

Multiobjective Optimization of Low-Specific-Speed Multistage Pumps by Using Matrix Analysis and CFD Method

Table 9

Range analysis of orthogonal test data.

IndexA B C D E F G H I J

H/m
 k 134.97734.40133.86234.62535.78435.47335.28135.36635.41235.087
 k 235.62735.35535.83136.04535.29535.25235.44735.65635.43436.535
 k 335.51336.36236.42435.44735.03835.39335.38935.09635.27134.495
 s 0.6501.9612.5621.4200.7460.2210.1670.5600.1632.040
η/%
 k 160.79560.93561.05961.11660.63060.73960.28560.53060.67860.600
 k 260.66160.83860.75460.96560.74760.75560.92060.89760.71361.795
 k 360.57160.25460.21459.94660.65060.53260.82260.60160.63659.632
 s 0.2240.6810.8441.1700.1170.2230.6350.3670.0772.163
P/kW
 k 11.9631.9271.8551.9362.0332.0272.0092.0152.0172.018
 k 22.0332.0072.0452.0532.0172.0002.0082.0222.0312.025
 k 32.0382.1012.1342.0451.9852.0072.0171.9981.9871.992
 s 0.0750.1740.2790.1160.0480.0270.0090.0240.0430.033