Research Article

Hydraulic Transients Induced by Pigging Operation in Pipeline with a Long Slope

Table 2

Summary of two accidents.

The first accidentThe second accident

Number of compressor21
Total time of pigging process20 Hours39.5 Hours
The length of drainage pipe150.0 m150.0 m
The drainage pipe sizeΦ159.0 × 8.7 mmΦ159.0 × 8.7 mm
The length of rupture2.6 m2.5 m
Maximum of air pressure1.01 MPa
Bursting pressure of tube20.83 MPa20.83 MPa