Reference Function Based Spatiotemporal Fuzzy Logic Control Design Using Support Vector Regression Learning
Figure 9
Control performance comparisons. From left to right in (a)–(g): catalyst temperature varying with time and space, manipulated input, and catalyst temperature at steady state.
(a) Controlled by a reference function based 3D FLC with Symmetric triangle reference function
(b) Controlled by a reference function based 3D FLC with Gaussian reference function
(c) Controlled by a reference function based 3D FLC with Cauchy reference function
(d) Controlled by a reference function based 3D FLC with Laplace reference function
(e) Controlled by a reference function based 3D FLC with Hyperbolic Secant reference function
(f) Controlled by a reference function based 3D FLC with Squared Sinc reference function