Research Article

Image Reconstruction Based on Homotopy Perturbation Inversion Method for Electrical Impedance Tomography

Table 2

Comparison of reconstructions for the second phantom with at four different noise levels.

HPIM CLIM
DE RE (s) DE RE (s)

5% 20 0.9974 0.1199 8.6813 43 0.9997 0.1186 17.8413
3% 27 0.5999 0.1923 12.1581 59 0.5993 0.1912 25.1848
1% 91 0.1999 0.1051 38.3450 190 0.2000 0.1034 77.1894