Table of Contents Author Guidelines Submit a Manuscript
Journal of Applied Mathematics
Volume 2013 (2013), Article ID 545147, 7 pages
http://dx.doi.org/10.1155/2013/545147
Research Article

Forming Mechanism and Correction of CT Image Artifacts Caused by the Errors of Three System Parameters

College of Information Science and Engineering, Shandong University of Science and Technology, Qingdao 266590, China

Received 27 January 2013; Accepted 30 March 2013

Academic Editor: Hang Joon Jo

Copyright © 2013 Ming Chen and Gang Li. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. A. C. Kak and M. Slaney, Principles of Computerized Tomographic Imaging, IEEE Press, New York, NY, USA, 1988. View at Zentralblatt MATH · View at MathSciNet
  2. B. K. P. Horn, “Fan-beam reconstruction methods,” Proceedings of the IEEE, vol. 67, no. 12, pp. 1616–1623, 1979. View at Google Scholar · View at Scopus
  3. M. Dennis, R. Waggener, W. McDavid, W. Payne, and V. Sank, “Processing X-ray transmission data in CT scanning,” Optical Engineering, vol. 16, no. 2, pp. 6–10, 1977. View at Google Scholar
  4. P. Dreike and D. P. Boyd, “Convolution reconstruction of fan beam projections,” Computer Graphics and Image Processing, vol. 5, no. 4, pp. 459–469, 1976. View at Google Scholar · View at Scopus
  5. G. T. Gullberg, C. R. Crawford, and B. M. W. Tsui, “Reconstruction algorithm for fan beam with a displaced center-of-rotation,” IEEE Transactions on Medical Imaging, vol. MI-5, no. 1, pp. 23–29, 1986. View at Google Scholar · View at Scopus
  6. Y. Sun, Y. Hou, and J. Hu, “Reduction of artifacts induced by misaligned geometry in cone-beam CT,” IEEE Transactions on Biomedical Engineering, vol. 54, no. 8, pp. 1461–1471, 2007. View at Publisher · View at Google Scholar · View at Scopus
  7. V. Patel, R. N. Chityala, K. R. Hoffmann et al., “Self- calibration of a cone- beam micro-CT system,” Medical Physics, vol. 36, no. 1, pp. 48–58, 2009. View at Publisher · View at Google Scholar
  8. L. Chen, Z. Wu, X. Liu, and M. Yao, “Analytical geometric parameter calibration algorithm for cone-beam CT,” Journal of Tsinghua University, vol. 50, no. 3, pp. 418–421, 2010. View at Google Scholar · View at Scopus
  9. J. Li, R. J. Jaszczak, K. L. Greer, and R. E. Coleman, “A filtered backprojection algorithm for pinhole SPECT with a displaced centre of rotation,” Physics in Medicine and Biology, vol. 39, no. 1, pp. 165–176, 1994. View at Publisher · View at Google Scholar · View at Scopus
  10. J. Li, R. J. Jaszczak, H. Wang, G. T. Gullberg, K. L. Greer, and R. E. Coleman, “A cone beam SPECT reconstruction algorithm with a displaced center of rotation,” Medical Physics, vol. 21, no. 1, pp. 145–152, 1994. View at Publisher · View at Google Scholar · View at Scopus
  11. H. Wang, M. F. Smith, C. D. Stone, and R. J. Jaszczak, “Astigmatic single photon emission computed tomography imaging with a displaced center of rotation,” Medical Physics, vol. 25, no. 8, pp. 1493–1501, 1998. View at Publisher · View at Google Scholar · View at Scopus
  12. Z. B. Wang, “Effect of center deviation on CT reconstruction images,” Acta Armamentarii, vol. 22, no. 3, pp. 323–326, 2001. View at Google Scholar · View at Scopus
  13. H. N. Lu, M. Yang, and L. Zhang, “A study on the reconstruction bias originating from error of focal distance of x-ray source,” Acta Armamentarii, vol. 24, no. 1, pp. 65–67, 2003. View at Google Scholar