Research Article
Active Power Oscillation Property Classification of Electric Power Systems Based on SVM
Table 1
Testing result of 16-machine 68-bus benchmark system.
| Kernel function | Signal type | No noise | 5% noise | 10% noise |
| Polynomial kernel function | | C1 | C2 | | C1 | C2 | | C1 | C2 | C1 | 72 | 1 | C1 | 70 | 3 | C1 | 66 | 4 | C2 | 4 | 43 | C2 | 6 | 41 | C2 | 10 | 40 | Precision | 95.80% | Precision | 92.50% | Precision | 88.30% |
| RBF kernel function | | C1 | C2 | | C1 | C2 | | C1 | C2 | C1 | 74 | 2 | C1 | 71 | 2 | C1 | 66 | 4 | C2 | 2 | 42 | C2 | 5 | 42 | C2 | 10 | 40 | Precision | 96.70% | Precision | 94.20% | Precision | 88.30% |
| Sigmoid kernel function | | C1 | C2 | | C1 | C2 | | C1 | C2 | C1 | 75 | 1 | C1 | 72 | 1 | C1 | 68 | 3 | C2 | 1 | 43 | C2 | 4 | 43 | C2 | 8 | 41 | Precision | 98.30% | Precision | 95.80% | Precision | 90.80% |
|
|