Research Article

Counterexample-Preserving Reduction for Symbolic Model Checking

Table 10

Experimental results of BMC-based MC with/without CEPRE.

Model Spec.Without CEPREWith CEPRE Max-
bound
N.O.C.Time (sec.) N.O.C.Time (sec.)

srg5Ptimo.ltl27256767.39113710.14320
Pti.gnv.ltl21010.1162990.0246
Pti.g.ltl210.016210.0161

abp4P2false.ltl75323.97275323.97217
P2true.ltl126398.14593697.75320*
Pold.ltl74999.08774999.48820*
Ptimo.ltl63322.50063322.51216
Pti.g.ltl119520.841119520.97620*

dme3P0.ltl35102524.20762
P1.ltl2160.0361670.0481

dme5Mdl.ltl900.044900.0480
Wat.ltl3670.0482740.0521
Ptimo.neg3670.0502770.0581

msi_w-transSched.ltl142351.076142351.07820*
Safety.ltl124398.441124398.44820*
Seq.ltl19070.064810.0523