Research Article

An Analytical Solution by HAM for Nonlinear Simulation of Deepwater SCR Installation

Table 2

Critical results.

Item = 500 m = 1000 m = 2000 m
(m) (m) (N) (m) (m) (N) (m) (m) (N)

HAM297.97499.41217071545.431004.094299371050.672006.54859997
OrcaFlex299.89499.91214430546.571002.774282281056.202003.68853240