Table 2

Comparison of the efficiency of some electrochemical methods in the determination of Hcy.

ElectrodeMethodsLOD (μmol L−1)LDR (μmol L−1)Reference

Carbon pasteHPLC with amperometric detection0.030.1–5[9]
Glassy carbonAmperometry0.060.1–60.0[10]
Carbon-nanotube pasteAmperometry4.65.0–200.0[11]
Carbon-nanotube pasteSWV0.080.1–210.0This work