Research Article
Microemulsion Liquid Chromatographic Method for Simultaneous Determination of Simvastatin and Ezetimibe in Their Combined Dosage Forms
Table 4
Accuracy and precision data for the determination of the studied drugs by the proposed MELC method.
| | SIM concentration (g/mL) | EZT concentration (g/mL) | | 10.0 | 20.0 | 30.0 | 20.0 | 30.0 | 40.0 |
| Intraday | | | | | | |
| 100.47 | 100.01 | 99.70 | 100.20 | 99.84 | 99.63 | ±SD | 0.51 | 0.27 | 0.62 | 0.60 | 0.44 | 0.57 | % RSD | 0.51 | 0.27 | 0.62 | 0.60 | 0.44 | 0.57 | % Error | 0.30 | 0.16 | 0.36 | 0.35 | 0.25 | 0.33 | Interday | | | | | | | | 100.12 | 99.97 | 99.89 | 100.04 | 100.08 | 99.81 | ±SD | 0.37 | 0.30 | 0.84 | 0.73 | 0.58 | 0.46 | % RSD | 0.37 | 0.30 | 0.84 | 0.73 | 0.58 | 0.46 | % Error | 0.21 | 0.17 | 0.49 | 0.42 | 0.33 | 0.26 |
|
|
Each result is the mean recovery of three separate determinations.
|