Research Article

Development of an HPLC-UV Method for the Analysis of Drugs Used for Combined Hypertension Therapy in Pharmaceutical Preparations and Human Plasma

Table 2

Parameters corresponding to linear regression obtained from the calibration curves for the plasma samples.

Drug substanceSlope SDIntercept SDCorrelation coefficientLinear range

OLM31947−5036.2 0.99950.4–25.6  g/mL
HCT25436−5846.70.99990.3–22  g/mL
VAL36544−1005.40.99980.3–15.5  g/mL
AML34770−109530.99980.1–18.5  g/mL