Research Article

Comparative Study of Novel Ratio Spectra and Isoabsorptive Point Based Spectrophotometric Methods: Application on a Binary Mixture of Ascorbic Acid and Rutin

Table 1

Determination of AA and RU in laboratory prepared mixtures by the proposed spectrophotometric methods.

Concentration Direct A_SumIso_RDA_SumIso_RDIso_PRDDDMCNRS
(µg/mL)
AARURURURUAAAAAAAAAAAAAA

84104.6999.40100.13101.22101.0691.20106.37102.40104.64102.84
88105.0199.5097.7899.2499.7598.71104.74103.43103.86103.47
12899.18100.48101.6299.7298.4998.48101.91100.2199.99101.32
812103.7598.6799.3698.6499.7596.20101.58100.12101.00100.49
121299.6099.12102.5098.9598.4196.93101.3699.91100.61100.75
161298.63100.1697.77101.26100.7591.0299.0498.0299.5898.09
201299.9499.35102.37101.20101.7990.8699.3998.48100.2198.68
816106.2798.9198.5399.1095.9497.47103.69102.69103.84102.56
1216101.07101.5796.0298.80100.1196.03102.66102.07103.03101.77
2016100.3199.0697.1999.9297.3496.12103.34102.77104.19102.93
820106.5899.5599.1299.35102.2196.33101.45101.15101.51100.54
202099.18101.5699.72100.35100.1396.94103.40102.56104.00102.76

Mean102.0299.7899.3499.8199.6595.52102.41101.15102.21101.35

SD2.880.972.050.981.832.732.001.711.811.64

RSD%2.821.212.060.981.842.861.951.691.771.62

Average of four determinations.