Research Article

UHPLC-PDA Assay for Simultaneous Determination of Vitamin D3 and Menaquinone-7 in Pharmaceutical Solid Dosage Formulation

Table 4

Accuracy studies of vitamin D3 and MK-7 by HPLC and UHPLC.

AnalyteConcentration after spiking
(μg mL−1)
HPLCUHPLC-experimental -experimental
Concentration found
(μg mL−1) ± SEM; RSD
(%) recovery
BIAS
Concentration found
(μg mL−1) ± SEM; RSD
(%) recovery
BIAS

Vitamin D337.537.53 ± 0.21; 1.18100.0837.55 ± 0.22; 1.48100.130.64 4.4
0.080.13
50.050.87 ± 0.18; 0.71101.7450.78 ± 0.21; 0.71101.56−4.16 8.7
1.741.56
62.562.48 ± 0.17; 0.4399.9762.57 ± 0.14; 0.33100.11−1.15 0.79
0.030.11

MK-737.537.12 ± 0.22; 2.0898.9737.26 ± 0.32; 2.5599.360.52 0.55
1.010.64
50.050.56 ± 0.21; 0.98101.1250.58 ± 0.42; 1.16101.16−0.29 0.46
1.121.16
62.562.79 ± 0.24; 1.98100.4662.27 ± 0.51; 0.4099.635.77 0.32
0.460.83

Actual concentration of vitamin D3 and MK-7 = 25 μg mL−1. All measurements were made in triplicate; SEM: standard error mean; RSD: relative standard deviation. Theoretical -value is 4.30 and -value is 19.0, at = 0.05.