Research Article

Voltammetric Determination of Anethole on La2O3/CPE and BDDE

Table 4

DPV anethole determination in the range of 0.7–17.5 mg L−1 in 0.1 mol L−1 acetate buffer, pH 6.0 (n = 3).

ElectrodeAnethole peak position (mV)a ± SDa (µA/mg L−1)b ± SDb (µA)rLOD (mg L−1)

Electrode diameter 3 mm, area 7.07 mm2
BDDE9650.135 ± 0.0030.050 ± 0.0130.99900.024
GCE9900.306 ± 0.0050.031 ± 0.0460.99950.011
CPE11550.546 ± 0.036−0.068 ± 0.0830.99360.006
CeO2/CPE 20%11250.341 ± 0.009−0.060 ± 0.0210.99890.010
La2O3/CPE 20%10950.885 ± 0.0160.076 ± 0.0690.99930.004
Electrode diameter 1.5 mm, area 1.77 mm2
GCE9700.022 ± 0.0010.0035 ± 0.00510.99890.148
CPE11100.111 ± 0.004−0.005 ± 0.0430.99830.030
CeO2/CPE 20%10750.227 ± 0.008−0.054 ± 0.0800.99780.014
La2O3/CPE 20%10800.449 ± 0.021−0.058 ± 0.0440.99590.007
La2O3/CPE 30%10950.350 ± 0.016−0.039 ± 0.0350.99580.009
La2O3/CPE 40%11000.332 ± 0.0100.029 ± 0.1100.99800.010