Research Article

Simultaneous Determination of Over-the-Counter Pain Relievers in Commercial Pharmaceutical Products Utilizing Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) Multivariate Calibration Model

Table 3

Figures of merits of the calibration set for the developed MCR-ALS model.

ParametersPARASACAFNPXIPF

Calibration range0.5–71–150.5–30.5–3.51–15
Slope1.00000.99991.00001.00000.9999
Intercept8.75 × 10−15−1.96 × 10−14−2.02 × 10−132.51 × 10−32.13 × 10−3
RMSECV0.1360.0450.1940.1520.064
SEP0.1530.0320.1700.1490.063
Bias2.64 × 10−24.12 × 10−3−2.58 × 10−23.22 × 10−23.11 × 10−3
RE (%)1.320.941.651.281.15
Coefficient of determination (r2)0.99980.99950.99930.99980.9996