Research Article

Carboxylated Multiwalled Carbon Nanotubes as Dispersive Solid-Phase Extraction Sorbent to Determine Eighteen Polychlorinated Biphenyls in Vegetable Samples by Gas Chromatography-Mass Spectrometry

Table 1

Retention times, characteristic ions, and their relative abundance of the 18 PCBs analyzed in the present study.

NoIUPAC numberIUPAC nameFormulaRetention time (min)Time window (min)Characteristic ions (m/z)Relative abundances (%)

1PCB282,4,4′-trichlorobiphenylC12H7Cl312.3735.00–13.00256/186/150100/68/18
2PCB522,2′,5,5′-tetrachlorobiphenylC12H6Cl413.59713.00–16.00292/220/110100/82/20
3PCB1012,2′,4,5,5′-pentachlorobiphenylC12H5Cl517.23316.00–18.00326/254/127100/59/18
4PCB813,4,4′,5-tetrachlorobiphenylC12H6Cl418.44818.00–19.50292/220/110100/40/15
5PCB773,3′,4,4′-tetrachlorobiphenylC12H6Cl418.913292/220/110100/43/13
6PCB1232′,3,4,4′,5-pentachlorobiphenylC12H5Cl520.06819.50–22.00326/254/127100/40/11
7PCB1182,3′,4,4′,5-pentachlorobiphenylC12H5Cl520.184326/254/127100/35/10
8PCB1142,3,4,4′,5-pentachlorobiphenylC12H5Cl520.710326/254/127100/46/12
9PCB1532,2′,4,4′,5,5′-hexachlorobiphenylC12H4Cl621.329360/290/145100/65/24
10PCB1052,3,3′,4,4′-pentachlorobiphenylC12H5Cl521.469326/254/127100/36/14
11PCB1382,2′,3,4,4′,5′-hexachlorobiphenylC12H4Cl622.68922.00–24.00360/290/145100/62/20
12PCB1263,3′,3,4,4′,5-pentachlorobiphenylC12H5Cl523.136326/254/127100/30/13
13PCB1672,3′,4,4′,5,5′-hexachlorobiphenylC12H4Cl624.17424.00–25.00360/290/145100/38/16
14PCB1562,3,3′,4,4′,5-hexachlorobiphenylC12H4Cl625.32825.00–26.00360/290/145100/34/15
15PCB1572,3,3′,4,4′,5′-hexachlorobiphenylC12H4Cl625.622360/290/145100/45/17
16PCB1802,2′,3,4,4′,5,5′-heptachlorobiphenylC12H3Cl726.25026.00–27.00394/324/162100/72/36
17PCB1693,3′,4,4′,5,5′-hexachlorobiphenylC12H4Cl627.47027.00–29.00360/290/145100/40/17
18PCB1892,3,3′,4,4′,5,5′-hexachlorobiphenylC12H3Cl729.42529.00–31.00394/324/162100/50/23

Quantitative ion.