Research Article

Functionalized Fe3O4 Magnetic Nanoparticle Potentiometric Detection Strategy versus Classical Potentiometric Strategy for Determination of Chlorpheniramine Maleate and Pseudoephedrine HCl

Table 2

The composition of the six fabricated sensors.

SensorIon-associatePlasticizer

1CPM—PTDBP
2CPM—CDDBP
3CPM—Fe3O4 nanoparticlesDBP
4PSE—PTDBP
5PSE—CDDBP
6PSE—Fe3O4 nanoparticlesDBP