Research Article

Functionalized Fe3O4 Magnetic Nanoparticle Potentiometric Detection Strategy versus Classical Potentiometric Strategy for Determination of Chlorpheniramine Maleate and Pseudoephedrine HCl

Table 7

Statistical comparison between the results obtained by the proposed sensors and the reported method for the determination of CPM and PSE in pure form.

ParameterMeanaSDVariancet testF test

CPMSensor 1100.040.8860.78540.484 (2.36b)1.445 (9.12b)
Sensor 299.890.7830.61340.265 (2.36b)1.850 (9.12b)
Sensor 399.971.0681.14160.384 (2.26b)1.006 (6.26b)
Reported method [23]c99.721.0651.1345

PSESensor 4100.060.8970.80440.943 (2.36b)1.271 (9.12b)
Sensor 5100.121.2561.57750.944 (2.31b)1.543 (6.39b)
Sensor 6100.011.0261.05270.951 (2.23b)1.029 (6.16b)
Reported method [23]c99.451.0111.0225

aAverage of six determinations; bfigures between parentheses represent the corresponding tabulated values of t and F at ; creported HPLC method using C18 column, flow rate 1.5 mL·min−1, mobile phase is a gradient elution of acetonitrile:phosphate buffer (15 : 85, v/v) for 5.5 min, (45 : 55, v/v) for 5.5–12 min, and (60 : 40, v/v) for 12–17 min at pH = 3 and UV detection at 220 nm.