Research Article

Selective Consecutive Determination of Desloratadine and Montelukast Sodium in Their Pure and Binary Dosage Form Based on Pencil Graphite Electrochemical Sensors

Table 3

Selectivity coefficients of DES- and MON-coated graphite sensors.

InterferingDES.RNK sensorMON.Cd. sensorCombined sensor
DESMON
KDES, BKMON, BKDES, BKMON, B

K+3.7 × 10−31.6 × 10−33.3 × 10−31.4 × 10−3
Na+4.4 × 10−33.1 × 10−34.1 × 10−33.2 × 10−3
NH4 +2.6 × 10−37.8 × 10−32.2 × 10−37.5 × 10−3
Ca2+1.6 × 10−33.9 × 10−31.3 × 10−33.6 × 10−3
Mg2+1.8 × 10−38.1 × 10−31.6 × 10−38.3 × 10−3
Mn2+2.1 × 10−38.6 × 10−32.2 × 10−38.7 × 10−3
Cu2+4.5 × 10−37.4 × 10−34.4 × 10−37.6 × 10−3
Fe2+5.1 × 10−36.8 × 10−35.3 × 10−36.6 × 10−3
Cd2+3.9 × 10−36.5 × 10−24.1 × 10−36.2 × 10−2
Avicel1.9 × 10−37.1 × 10−31.5 × 10−37.3 × 10−3
Mg stearate2.3 × 10−34.5 × 10−31.9 × 10−34.3 × 10−3
Dextrose3.3 × 10−36.2 × 10−33.1 × 10−35.8 × 10−3
Desloratadine1.1 × 10−21.3 × 10−2
Montelukast1.5 × 10−21.2 × 10−2