Research Article

Simultaneous Electrochemical Detection of Pb and Cd by Carbon Paste Electrodes Modified by Activated Clay

Table 1

Comparison of the performance of some electrodes with other analytical methods for lead and cadmium.

Electrode materialTechnique usedSolventLimit of detectionReference
Pb2+Cd2+

Ce-Zr/GCESWASVDistilled water5980 μM[5]
RGO-GNPsSWASVDistilled water0.00058 μM0.00071 μM[6]
GCE-MWCNT/poly-PCV/BiDPASVDistilled water0.00193 μM0.00178 μM[8]
Fe3O4/MWCNTs/LSG/CS/GCESWASVDistilled water0.00034 μM0.00089 μM[21]
BiPs-CNFs/[EMIM][NTf2]/CPESWASVDistilled water0.00058 μM0.00222 μM[25]
ZnFe2O4-GCEDPASVDistilled water0.00541 μM0.02224 μM[26]
GCE/ZSM-5/PtDPVDistilled water0.01196 μM[27]
CPE-ACCSWVDistilled water0.15513 μM0.24227 μMThis work
CPE-ACCSWVTap water0.08438 μM0.46522 μMThis work