Research Article
An Estimation Model on Electricity Consumption of New Metro Stations
Table 5
Prediction accuracy of the SVR model.
| Sample ID | Actual value | Prediction value (×106 kWh) | SD | APE (%) | RRMSE (%) /CC |
| 1 | 10.430 | 10.243 | 0.201 | 1.79 | 1.39/0.89 | 2 | 10. 043 | 10.026 | 0.112 | 0.17 | 3 | 10. 334 | 10.159 | 0.193 | 1.70 | 4 | 9.820 | 10.032 | 0.119 | 2.16 | 5 | 10.635 | 10.393 | 0.140 | 2.28 | 6 | 10.661 | 10.562 | 0.160 | 0.93 | 7 | 10.289 | 10.242 | 0.201 | 0.46 | 8 | 10.193 | 10.073 | 0.142 | 1.17 | 9 | 10.199 | 10.249 | 0.185 | 0.50 | 10 | 10.111 | 10.034 | 0.204 | 0.77 |
|
|