Research Article
An Estimation Model on Electricity Consumption of New Metro Stations
Table 8
Impact of influence factors on model prediction result.
| Missing variable | Maximum APE | CC |
| Average temperature | 9.02% | 0.37 | Relative humidity | 8.52% | 0.48 | Area of concourse | 6.66% | 0.76 | Area of platform | 7.60% | 0.71 | Area of staff accommodation room | 6.58% | 0.84 | Area of plant room | 5.98% | 0.88 | Quantity of escalators or elevators | 6.76% | 0.81 | Height of escalators or elevators | 6.89% | 0.81 | Number of passengers | 6.00% | 0.74 |
|
|