Research Article
Calculation of Spotting Particles Maximum Distance in Idealised Forest Fire Scenarios
Figure 6
(a) Smoke scalar concentration for 20000 kW/m short grass fire; (b) maximum height and longitudinal distances during particle trajectory as a function of particle size; and (c) probability of particles spotting distances as a function of particle size.